Omega-engineering DIGITAL INPUT/OUTPUT PCI-DIO96 User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 31
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
INTE Interrupt enable (local):
0 = disabled, 1 = enabled (default)
INTPOL Interrupt polarity:
0 = active low (default), 1 = active high
INT Interrupt status:
0 = interrupt not active, 1 = interrupt active
PCINT PCI interrupt enable:
0 = disabled (default), 1 = enabled
LEVEL/EDGE Interrupt trigger control:
0 = level triggered mode (default), 1 = edge triggered mode
INTCLR Interrupt clear (edge triggered mode only):
0 = N/A, 1 = clear interrupt
ISAMD ISA mode enable control (must be set to 1)
0 = ISA mode disabled, 1 = ISA mode enabled (default)
5.3 BADR2
BADR2 is not used.
10
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 30 31

Comments to this Manuals

No comments