FACTORY SET OUTPUT OPTIONS
22
DUAL RELAY OR DUAL SSd OUTPUT MODELS
The table below details the factory set output options. rLY2 is a 1A
electromechanical relay, and SSd1/SSd2 is an identical second SSR
drive output.
QUICK START (page 1a) or SET-UP (page 5) follow steps 1
and 2 ignore step 3 and proceed straight to step 4.
Factory Option CN9411 offers the ability to change the allocation of
SP1 to terminals 5 and 6.
To make this selection during the initial configuration in either
QUICK START (page 1b) or SET-UP (page 5), start from step 3.
3 TO SELECT SP1 (Main setpoint output device)
From the display
press and hold button then press the once
to display
rLY2
in the lower display.
Product
Code
Terminals
34 56
CN9411
CN9422
rLY1 (2A) rLY2 (1A)
SSd1 SSd2
(+) (-) (+) (-)
Factory Options CN9411 and CN9422 pre-allocate SP1 to
terminals 3 and 4.
Note: Output device rLY/rLY1 is rated 2A
Output device rLY2 is rated 1A
SP1D